Model NO.: KHA-220
Principle: Absorption Spectrometry, Turbidimetry
Reaction Time: Max 15 minutes
Absorption Range: 0-4.0ABS
Cuvette: 81 Cuvettes
Transport Package: Carton
Specification: 1000*730*1100mm
Origin: China
HS Code: 902780990
KHA-220 Full-auto Biochemistry Analyzer

120 tests / hour                   30 sample positions
60 reagent positions            81 reaction positions   
 

Technical Feature   
                                                   

Performance

Type: Discrete Automatic
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 120 tests/hour (without ISE)
Test Method: End-point, Fixed-time, kinetic
            Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
              Insert emergency at any time
Online Sample: 30 samples/ batch, unlimited batch input
Reaction Time: Max 15 minutes
Reaction Volume: Mini 150μl
Cuvette: 81 cuvettes

Optical System

Light Source: Halogen-tungsten lamp, 12V/20W
More than 2000 hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system

Sample system

Sample Tray: 30 positions
Sample Volume: 2-100μl, 0.1μl by step,
Sample Probe: Liquid level detection, anti-collision protection and inventory checking,
              have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior

Others

Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V   50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C - 30°C

Reagent System

Reagent Volume: 20-500μl, 1μl by step
Reagent Tray: 60 positions, open system
Reagent Probe: : Liquid level detection, anti-collision protection and inventory checking,
               have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available
dead volume < 1ml

Temperature Control System

Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3 minutes
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.2°C

Control and Calibration

Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
             Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
            QC chart: L-J, Cumulative, Twin Plot
QC Rules: Multi-rule; default: Westguard
Lithium iron phosphate battery

1:Lifepo4/Lithium iron phosphate cell is adopted,
2: Using high quality and strong BMS protection board, with high current capacity
3: Adopting innovative pack mode, the battery has excellent heat dissipation ability
4: Stable quality and safety guarantee
5: At least 2 years quality assurance
6: OEM, ODM

7: High quality after-sales service conditions

8:Used in solar energy system, electric bicycle, electric motorcycle, electric four wheeled vehicle, electric truck, electric vehicle, etc

Lifepo4 Battery,Catl Lfp Battery,Long Life Lfp Battery,Plastic Case Lifepo4 Battery

MAIN NEW ENERGY CO.,LTD , https://www.main-newenergy.com